Preview build: site_demo

Controls engineer · Integrator · Developer

From the field device to the dashboard.

PLC and motion programming, building automation, industrial HVAC controls and the custom software and SQL that tie it all together. One engineer across the whole stack.

0
PLC platforms
0+
Servo/drive families
0
Field protocols: BACnet & Modbus
0
Engineer, full stack
  • Allen-Bradley
  • Siemens TIA Portal
  • Omron Sysmac
  • Keyence KV
  • Yaskawa
  • FANUC
  • Tridium Niagara 4
  • JACE
  • BACnet IP / MS/TP
  • Modbus RTU / TCP
  • C# / .NET
  • JavaScript
  • PHP
  • SQL Server
  • Linux
  • Windows

Services

Everything between the sensor and the screen.

Pick a discipline to see what's covered. Every engagement is documented, version-controlled and handed over with the source.

Featured: RTU Dashboard

A live 3D rooftop monitoring dashboard: real-time alarms, trends and SQL telemetry.

See the demo →

Featured project

Rooftop RTU Monitor

A projector-friendly 3D view of a building roof. Every rooftop unit shows live status, alarms pulse on the map, and one click zooms into fault details backed by SQL telemetry.

  • 3D roof map built with Three.js, with click-to-zoom fault inspection
  • Alarm engine with priorities, acknowledgements and history
  • Trend graphs over SQL Server, PostgreSQL or SQLite
  • C# .NET server on Windows and Linux, with sign-in and roles
  • Air-gapped camera link option: reads a BMS screen one way only, with nothing sent back

The demo runs on simulated data. Sign-in may be required.

demo
Dashboard overview: 3D roof with RTU status labels and active alarm list Top-down view of the roof with every unit Zoomed-in alarm on a single rooftop unit Trend graph of unit telemetry
bacnet-health › site scan SCANNING
0health score
  • Healthy 0
  • Stale data 0
  • Offline 0

    In-house product

    BACnet Data Health Analyzer

    Most building systems don't fail loudly. A sensor freezes, a controller drops off the trunk, or a point quietly reports the same value for weeks. The analyzer scans the network and scores every device and point, so problems surface before occupants notice.

    • Finds offline and intermittent devices on BACnet IP and MS/TP
    • Flags stale, flat-lined and out-of-range points
    • Health score per device, trunk and site
    • Reports you can hand to a facility manager

    Extended capability

    Industrial HVAC automation

    Sequences that hold setpoint, save energy and fail safe, from a single rooftop unit to a full central plant.

    Air handling unit: outside air and return air mix, pass through filter, cooling and heating coils and supply fan DAMPERS FILTER CHW COIL HW COIL SUPPLY FAN OASARA OA TEMP38.6°F MIXED AIR57.9°F CHW VALVE34% FAN SPEED72% SUPPLY AIR55.0°F

    Air handlers & RTUs

    Economizer logic, discharge air reset, static pressure control, smoke and freeze protection.

    Central plants

    Chiller and boiler staging, condenser water optimization, lead/lag rotation and failover.

    Terminal units

    VAV and fan-coil balancing, occupancy scheduling and demand-controlled ventilation.

    Process cooling

    Industrial and data-room cooling with redundancy, alarming and trending a plant can trust.

    How it works

    A clear path from walk-down to handover.

    1. 01

      Discover

      Site walk, I/O and point lists, existing code and network survey.

    2. 02

      Design

      Sequences of operation, architecture, database and UI plan.

    3. 03

      Build

      PLC, Niagara and software development, tested against simulation first.

    4. 04

      Commission

      Point-to-point checkout, servo tuning, functional tests on site.

    5. 05

      Support

      As-built documentation, source handover, remote monitoring and support.

    Have a line, a building or a dataset that needs attention?

    Tell me about the equipment and the goal. I'll reply with how I'd approach it.

    Discuss a project